Wassail Walk Friday, Nov. 27 · 27 days 19 hrs See the route →
Skip to content

← New Franklin ordinances

New Franklin Specific Standards ordinance (§ 415.170)

Chapter 415: Floodplain Management · Article V. Provisions for Flood Hazard Reduction

In all areas identified as numbered and unnumbered A Zones and AE Zones, where base flood elevation data have been provided as set forth in Article V, Section 415.160(B), the following provisions are required:

1. Residential construction. New construction or substantial improvement of any residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to one (1) foot above base flood elevation.

2. Non-residential construction. New construction or substantial improvement of any commercial, industrial or other non-residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to one (1) foot above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood elevation the structure is water-tight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this Subsection are satisfied. Such certification shall be provided to the Floodplain Administrator as set forth in Article IV, Section 415.140(9).

3. Require, for all new construction and substantial improvements, that fully enclosed areas below lowest floor used solely for parking of vehicles, building access or storage in an area other than a basement and that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria:

a. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided; and

b. The bottom of all opening shall be no higher than one (1) foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.

Official source: New Franklin City Code, page 97 of the city's PDF

Last checked October 30, 2026. The city's official copy controls; this page is a reading copy, not legal advice.