Wassail Walk Friday, Nov. 27 · 27 days 20 hrs See the route →
Skip to content

← Boonville ordinances

Boonville General standards ordinance (§ 7.5-51)

Chapter 7.5: Floodplain Management · Article IV. Provisions for Flood

(a) No permit for floodplain development shall be granted for new construction, substantial improvements, and other improvements, including the placement of manufactured homes, within any numbered or unnumbered A zones and AE zones, unless the conditions of this section are satisfied.

(b) All areas identified as unnumbered A zones on the FIRM are subject to inundation of the 100- year flood; however, the base flood elevation is not provided. Development within unnumbered A zones is subject to all provisions of this chapter. If flood insurance study data is not available, the community shall obtain, review, and reasonably utilize any base flood elevation or floodway data currently available from federal, state, or other sources.

(c) Until a floodway is designated, no new construction, substantial improvements, or other development, including fill, shall be permitted within any numbered A zone or AE zone on the FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community.

(d) All new construction, subdivision proposals, substantial improvements, prefabricated structures, placement of manufactured homes, and other developments shall require:

(1) Design or adequate anchorage to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy;

(2) Construction with materials resistant to flood damage;

(3) Utilization of methods and practices that min-

imize flood damages;

(4) All electrical, heating, ventilation, plumbing,

air-conditioning equipment, and other service facilities be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding;

(5) New or replacement water supply systems

and/or sanitary sewage systems be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters, and onsite waste disposal systems be located so as to avoid impairment or contamination; and

(6) Subdivision proposals and other proposed

new development, including manufactured home parks or subdivisions, located within special flood hazard areas are required to assure that:

a. All such proposals are consistent with the need to minimize flood damage; b. All public utilities and facilities, such as sewer, gas, electrical, and water systems are located and constructed to minimize or eliminate flood damage; c. Adequate drainage is provided so as to reduce exposure to flood hazards; and d. All proposals for development, including proposals for manufactured home parks and subdivisions, of five acres or 50 lots, whichever is lesser, include within such proposals base flood elevation data.

(e) Storage, material, and equipment.

(1) The storage or processing of materials within

the special flood hazard area that are in time of flooding buoyant, flammable, explosive, or could be injurious to human, animal, or plant life is prohibited.

(2) Storage of other material or equipment may

be allowed if not subject to major damage by floods, if firmly anchored to prevent flotation, or if readily removable from the area within the time available after a flood warning.

(f) Agricultural structures. Structures used solely for agricultural purposes in connection with the production, harvesting, storage, drying, or raising of agricultural commodities, including the raising of livestock, may be constructed at-grade and wetfloodproofed provided there is no human habitation or occupancy of the structure; the structure is of single-wall design; there is no permanent retail, wholesale, or manufacturing use included in the structure; a variance has been granted from the floodplain management requirements of this chapter; and a floodplain development permit has been issued.

(g) Accessory structures. Structures used solely for parking and limited storage purposes, not attached to any other structure on the site, of limited investment value, and not larger than 400 square feet, may be constructed at-grade and wetfloodproofed provided there is no human habitation or occupancy of the structure; the structure is of single-wall design; a variance has been granted from the standard floodplain management requirements of this chapter; and a floodplain development permit has been issued.

Official source: City of Boonville official Code of Ordinances (online): look up Sec. 7.5-51

Text from Supplement 8 (December 2025), through Ordinance 4678 of December 16, 2024.

Last checked October 30, 2026. The city's official copy controls; this page is a reading copy, not legal advice.